DRAINING THE USED TANK
Turn the left valve "AIR FLOW" on the panel to
"Pressurize" position, right valve to "Used" po-
sition (Fig.13), open the used fluid hose valve
(Fig.14), then open the workshop air valve, and
the fluid in used tank is decreased;
Fig 13.
New fluid hose: closed
Used fluid hose: open
Fig 14.
Fig 15.
2. When all fluid is drained from the old tank,
reset all valves to the OFF position.
DRAINING THE NEW TANK
Turn the left valve "AIR FLOW" on the panel
to "Pressurize" position, right valve to "New"
position (Fig.16), open the new fluid hose valve
(Fig.17), then open the shop air valve, and the
fluid in the new tank is decreased;
Fig 16.
Fig 17.
External tank
2. When all fluid is drained from the new tank,
reset all valves to the OFF position.
· 16 ·
New fluid hose: open
Used fluid hose: closed