Motor is running,
voltmeter shows no
voltage. Sockets
are without power
Engine runs, but
very unevenly and
unevenly
Cable starter
is blocked and
cannot be pulled
through - engine
will not start.
Cable starter
can be pulled
through with
resistanceMotor
starts
not.
38
Possible
cause
Starting current
of loads too high
Incorrect fuel
or oil
Cable starter
possibly
defective
Incorrect
commissioning
Solution
Contact customer service and describe
the problem. Inform customer service
which appliances were connected to the
appliance during the last use.
Check that the air filter is firmly seated
and undamaged. The air filter must not
draw false air. Clean any dirt from the air
filter core. Only refuel the appliance with
unleaded petrol (normal petrol, Super,
Super Plus). Never mix other additives or
oils into the gasoline and do not use E10.
Remove the cable starter. If it can be
pulled through with resistance when
dismantled, the starter is in good
condition. If the cable pull can be pulled
through without resistance, it is defective.
Contact our customer service and
describe the problem.
Please carefully follow all the steps for
preparing and switching on the motor in
section Commissioning, p. 21.