5.3 Time configuration and synchronisation page

The "Time Configuration" page is divided into two parts. One is used to set the time zone,
the other to set the synchronisation mode.
The information displayed is described below:
- Time zone: using the drop-down menu, it is possible to choose the time zone (summer/winter
time is managed automatically according to time zone selected). It is also possible to configure a
non-defined zone by default in the drop-down menu ("PROG").
When "PROG" is selected in the drop-down menu, this function can be used to define the time,
month, rank and fixed day for changes of season:
- NTP Mode: used to select one of three mode types:
o Unicast: In Address IP 1, enter the IP address of the NTP server. In this case, it is the clock
that calls the NTP server.
Furthermore, it is possible to create a redundancy (if the first server does not reply, the second
one is called, etc.). This is why you can enter up to five server addresses.
(IP Address 1/2/3/4/5).
The Periodicity field sets the frequency with which the clock calls the configured NTP servers.