3.2 Clock with external power supply

For external power supply Cristalys clock : connect the low voltage power supply, 6V to 24 V
AC or DC on terminals 3 and 4.
Time synchronisation
Power supply 6V to
24 V AC or DC,
minimum 10 mA without
polarity distinction
The external power pack must
be SELV-type, supplying voltage
contained between 6 and 24V AC/DC, 10 mA minimum and in accordance with the limited
power supply criteria of the EN60950 standard § 2.5.
Do not insert batteries if an external power supply is connected.

3.3 Link-up to a time distribution network

Cristalys clocks can be synchronised by Minute or ½ minute //, or IRIG-B/AFNOR time
distribution network.
Connect the time coded line to terminals 1 and 2 on the terminal strip.
Time distribution type has to be configured in the technician menu (see page 32)
Time synchronisation, Minute, ½ minute // from
12 to 48V or IRIG-B/AFNOR impuls
Power supply

3.4 Installation

Setting of the table bracket (if supplied)
(in the 2 notches of the wall bracket).
Fit the wall bracket using the plugs and screws supplied.
143
100
Reset
Remark : There is no
polarity, but if there is
several clocks, they have
to be connect in the same
order.
Reset
Sel.
Anti-theft locking
screw
Sel.
Fixing
points
Diag.: 2
23