2.
INSTALLATION AND PRELIMINARY OPERATIONS
Once the machine is out of the packaging
and its integrity, and that of the accesso-
ries has been checked, place it on a flat,
horizontal surface and if necessary, use
the adjustable feet to make sure it is cor-
rectly level:
• Turn the feet to the left to raise the
machine up to a maximum of + 1 cm;
• Turn the feet to the right to lower the
machine.
It is advisable to install a softener and
then a mesh filter on the external part of
the plumbing system, during preliminar-
ies and after levelling the machine.
In this way impurities like sand, particles
of calcium, rust etc.. will not damage the
delicate graphite surfaces and durability
will be guaranteed.
Following these operations, connect the
plumbing systems as illustrated in the
following figure.
48
Avoid throttling in the connecting
tubes.
Assess that the drain pipe is able to
eliminate waste.
Mesh filter
Softener
Drain Ø50 mm
Fig. 4
2.1
CABLE STRIP COVERING
(optional)
Once the machine has been levelled and
connected to the power and water mains,
use the cable strips (optional) to cover up
the wiring, as shown in the figure.
2.2
WARNING
Monitoring of water recipe to keep it with-
in required levels and maintenance of fil-
tration system is the user's responsibility.
Failing to meet and maintain water at the
following levels will void the entire war-
ranty:
Fig. 5
2.3
The machine must always be protected
by an automatic omnipolar switch of
suitable power with contact openings
that permits the complete disconnec-
tion under conditions of overload cate-
gory III.
Simonelli Group is not liable for any
damage to people or objects due to not
observing current security measures.
Fig. 6
WATER SPECIFICATIONS
• total hardness 50-60 ppm (parts per
million)
• water line pressure between 2 – 4bar
and water to be cold
• min flow rate: 200 l/hr
• filtration level below 1.0 micron
• tds (total dissolved solids) level
between 50 – 250 ppm
• alkalinity level between 10 – 150 ppm
• chlorine level less than 0.50 mg/l
• Ph level between 6.5 and 8.5.
ELECTRICITY
SPECIFICATIONS
CAUTION
RISK OF SHORT CIRCUITS