3.5.3.1.5 Export File
In this menu, a "presets.csv" file is created in which all (up to) 99 tool configurations are saved. The
precondition is that the SD card is inserted in the setting tool.
3.5.3.1.6 iCounter
iCounter
The interval counter can be activated or deactivated in this menu. The iCounter shows how many
fasteners have been set since activating the counter. The activated iCounter appears on the start screen
beneath the status bar, see chapter 2.5.1.
Reset
This item can be used to reset the interval counter.
3.5.3.2 Spindle out
The spindle out time can be adjusted in this menu.
3.5.4 Load Setup
A previously saved tool configuration can be loaded.
3.5.5 Services
3.5.5.1 FW Update
A firmware update can be performed in this menu. The precondition is that the current firmware is saved
on the inserted SD card.
3.5.5.2 Factory Reset
The tool can be reset to the factory settings in this menu.
3.5.5.3 Calibration
Trigger
The trigger can be calibrated in this menu. This is only necessary when the trigger no longer reacts
reliably. Please follow the instructions on the display.
Spindle
The spindle can be calibrated in this menu. This is only necessary when the spindle no longer reacts
reliably. Please follow the instructions on the display.
3.5.6 Lock / Unlock
The setting tool can be locked or unlocked in this menu to prevent unauthorised use.
3.5.7 Emergency Mode
Emergency mode can be started here. Alternatively, emergency mode can be started via quick access by
pressing the "Arrow up" key and the "Arrow down" key. Quick access can be deactivated in the menu,
see chapter 3.5.2.5.