OPERATING INSTRUCTIONS
5
Commissioning
en
5.1
Test instructions
6
Technical data
Table 6: Technical data
Performance
32
O P E R A T I N G I N S T R U C T I O N S | EFS/EFM50-2
Figure 8: Axial outlet
Close the cover (8).
Commissioning the safe motor feedback systems requires that the manufacturer of the
connected drive system has complied with the safety requirements for the drive system
design, as described in the "HIPERFACE DSL
Ensure that an EFS50-2/EFM50-2 safe motor feedback system and not an
EFS50-0/EFM50-0 standard motor feedback system is being used during commis‐
sioning. This must be verified by reading out the type name (resource 083h).
Additionally, at least one test message must be sent in order to verify this (see the
"HIPERFACE DSL
®
Safety" implementation manual).
If the position offset of the motor feedback system is changed using the 101h
("Set position") resource or the 108h ("Factory settings") resource, it is then
necessary to verify that the sensor is providing the required position value.
Further inspection measures are not required during operation.
WARNING
SAFETY NOTE
The safe motor feedback system has a maximum service life
page
32). After this time, it must be taken out of service. The bearing service life
must be taken into account in addition to the mission time. The parameter which is first
reached depending on the application determines the time when the system must be
taken out of operation.
The motor feedback system's construction year can be found in the the serial number
(SN) on the device label or on the packaging label (YYWW).
YY = represents the year (without century)
WW = represents the calendar week of the last manufacturing process.
EFS50-2 ...21A
®
Safety" implementation manual.
(see "Technical data",
EFS50-2 ...23A
EFM50-2 ...21A
EFM50-2 ...23A
8019321/2024-10-01 | SICK
Subject to change without notice