4.2
Shielding connection
4.3
Motor feedback system signals
8019321/2024-10-01 | SICK
Subject to change without notice
Diagram 2
Typ. current consumption (A)
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
100
200
Time after switching on (μs)
7 V
8 V
12 V
Figure 3: Configuring the switch-on current
Ensure that the supply voltage to the motor feedback system's DSL plug (7) is from
+7 V to +12 V.
NOTE
A suitable encoder shield connection to the ground or to the motor shield is required for
smooth operation.
For a motor feedback system with:
Spring plate stator coupling
coupling (14).
Elastomer stator coupling
wire (24) and a shield connection (25).
The motor feedback system has the following signals:
HIPERFACE DSL
®
interface:
DSL+: Encoder supply voltage with a modulated positive data signal.
DSL–: Encoder ground connection with a modulated negative data signal.
Temperature sensor:DSL–: Encoder ground connection with a modulated negative data
signal.
T+: Positive potential for the passive temperature sensor/ temperature resistor.
T+: Negative potential for the passive temperature sensor/ temperature resistor