5.2.2
measuring principle
When the fluid flows through the pipe, the oval rotors which contain
magnets turn (see Fig. 1). The displacement of magnets lead to
a variation of magnetic field. The sensor measures the variation of
the magnetic field and converts the signal into a frequency. The
frequency is available at both the NPN transistor and Reed switch
outputs.
Fig. 1
Running/displacement of oval rotors
The remote instrument converts the frequency into a flow rate by
using the correct K factor.
8
English
Type 8077
Description
5.3
Description of the engraving
Type 8077 Flow Sensor
1
Model
567206N
2
2-100LPH
Flow Range
3
Max Pressure
1000kPa/55Bar
4
Max Temp
5
K Factor
999.3 ppL
6
Serial No
Fig. 2
Engraving of the device
1. Order code of the device
2. Flow rate measuring range
3. Max. pressure
4. Max. temperature
5. K factor (specific)
6. Serial number
120°C