ADJUSTING TOP BURNER PRIMARY AIR (7 KW)
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the screw (D).
5 - Set the burner mount (E) at a distance of 20
mm, and tighten the screw (D).
6 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
ADJUSTING TOP BURNER PRIMARY AIR (10 KW)
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the screw (D).
5 - Set the burner mount (E) at a distance of
20 mm, and tighten the screw (D).
6 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
ADJUSTING OVEN BURNER PRIMARY AIR
Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing, after the oven burner air
bushing has been replaced (see page 29).
Before making this adjustment, check that
the gas supply pressure is the same as the
rated pressure for the type of gas in use
(see table at back of manual).
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Remove the bottom plates (A) and the grid(B)
from the oven.
C
A C
B
C
A C
B
B
A
- 25 -
E
D
IDM-39617002000.tif
E
D
IDM-39617002100.tif
IDM-39617003100.tif
English
IT
GB
DE
FR
ES