CHECKING GAS PRESSURE
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Undo the screw (D) of the pressure connection.
5 - Connect the pressure gauge (E) to the pressure
test point (F).
6 - Turn the gas supply tap back on.
7 - Light all the burners and turn the knobs to the
full flame setting (see page 10), then check that
the pressure reading complies with the values
provided in the table at the back of the manual.
8 - Turn off the burners, disconnect the pressure
gauge and return all components to their initial
condition on completion of the operation.
TROUBLESHOOTING
The appliance has been tested before being put
into service. The information provided below is in-
tended to assist in the identification and correction
of any anomalies and malfunctions which might oc-
cur during use. The user can solve some of these
Faults
Smell of gas
The pilot light does not ignite
The pilot light goes out

FAULT

problems himself, but for others specific tech-
nical knowledge or skill is required, and so they
must only be carried out by qualified staff with rec-
ognised experience acquired in the specific sector
of operation.
Causes
Occasional leak because flame
has gone out
The spark ignition devices are not
working
Air in pipelines due to long period
out of use
The thermocouple has not
warmed up enough
- 15 -
C
E
A C
B
Remedies
Turn off the gas supply tap and
ventilate the room
Check that the ignition devices are
in good working order
Light by hand with a naked light
Important
Contact the after-sales
service
Make more attempts to light the
Make more attempts to light the
F