7 - Check that the safety device is operating cor-
rectly.
8 - Check that there are no gas leaks.
9 - Check that the nameplates specify the correct
gas for the country of use.
RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed. In particular,
turn off the gas supply tap, cut off the elec-

ADJUSTING GAS CONTROL VALVE MINIMUM SETTING

(TOP BURNERS)
Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
dure has been carried out (see page 20). Be-
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Fully screw the injector.
6 - After making the setting, seal the screw with
paint.
7 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.

ADJUSTMENTS

tricity supply using the master switch and
prevent access to all devices that might
cause unexpected health and safety haz-
ards if turned on.
fore making this adjustment, check that the
gas supply pressure is the same as the rat-
ed pressure for the type of gas in use (see
table at back of manual).
- 23 -
C
A C
B
8
IT
GB
DE
FR
ES
D
IDM-39614601800.tif