W
Accessory parts for use in explosive areas must comply with the
requirements stipulated in the European directives and national laws.
W
Components may only be exchanged for original spare parts that are
also approved for use in explosive areas.
W
Devices in ex areas must be cleaned regularly. The intervals must be
stipulated by the operator in accordance with the local ambient
conditions.
W
After service and/or maintenance, all barriers and warnings must be
returned to their original locations.
W
Disassemble the device as soon as malfunctions occur. Maintenance of
internal components cannot be conducted on site. Send the device to the
manufacturer for inspection.
Visual
Activity
inspection
(monthly)
Visually inspect the
integrity of the
solenoid coils, remove
dust deposits
Inspect the integrity
and function of the
electrical system
Inspect the entire
system
1) Definition acc. to IEC 60079-17

Cleaning and servicing

Penetration of contamination and fluids can lead to malfunctioning.
This no longer guarantees the safe function of the solenoid coils.
O Maintain the highest standards of cleanliness when working on the
system.
O Do not use high-pressure cleaners.
Damage to the surface caused by solvents and aggressive detergents!
Aggressive detergents can cause damage and premature ageing to the
solenoid coil seals.
O Only use water for cleaning and, if necessary, a mild detergent.
O Never use solvents or strong detergents.
O Do not use high-pressure cleaners.
To clean the 30MM-ATEX solenoid coils:
1. Make sure that all relevant system parts are not under voltage or
pressure.
2. Clean the 30MM-ATEX solenoid coils using a slightly damp cloth. Only
use water to do this and, if necessary, a mild detergent.

Spare parts

When ordering spare parts, include the ID number located on the devices
(label, rating plate).

11 Technical Data

General data
ATEX identification
Cable diameter
Cable cross-section
Protection class according to EN 60529/IEC 529
Mounting position
Configuration
Opening duration
Ambient temperature – Operation with AC current
W
Individual operation/battery assembly
Close-up
Detailed
1)
1)
inspection
inspection
(every 6 months)
(every 12 months)
X
Responsibility of the operator
NOTICE
See "ATEX –
Information on
explosion protection"
4.5–7 mm
0.5–1.5 mm
IP 65
Any
Can be assembled
into blocks
ED 100%
-20°C to +60°C
General data
Ambient temperature – Operation with DC current
W
Individual operation/battery assembly
Max. permissible medium temperature
W
Battery assembly
W
Minimum distance
12 Disposal
Dispose of the packaging and used parts of the 30MM-ATEX solenoid coils
1)
in accordance with the currently applicable regulations in the country
where the device is used.
X
2
8
-20°C to +50°C
80°C
Yes