Fig. 22: Pump filling
C
Fig. 23: On/off switch und power supply con-
nection
60
CAUTION
Damage to property due to dry run!
If the pump runs dry, the mechanical seals will be damaged.
• Fill the pump with water and vent it before commissioning.
Pump filling
1.
Unscrew the seal and remove it.
2.
Fill the pump with clear water via a funnel (Fig. 22).
3.
Reinstall the seal.
NOTICE
The level sensor must be correctly connected to the control device.
A faulty contacting or a measuring signal outside 4-20 mA is displayed as
an error and the system is switched to tap water mode.
Commissioning
1.
Check installation and impermeability of all connections (remove front cover if neces-
sary).
2.
To fill the replenishment reservoir, open the tap water inlet.
⇒
After approx. 30 seconds, the tank is filled.
A
3.
Check to ensure correct closing of the replenishment and impermeability.
4.
Check that the pump on/off switch is set to ON (Fig. 23 – A).
5.
Check that the motor power supply plug (Fig. 23 – C) is properly connected.
6.
Connect the mains plug to the power supply.
⇒
The control panel of the control device is activated.
7.
Select the preferred menu language (Fig. 24).
B