Manuel de référence
00809-0103-4801
HART 5 avec arborescences de menus de diagnostic
Illustration 2-6 : Présentation
Home
1 Overview
2 Configure
3 Service Tools
Overview
Status
1 Status
1 Device Status: Good
2 Primary Purpose Variable
2 Communications: Polled
3 Shortcuts
Primary Purpose Variable
1 Pressure
2 Analog Output
Shortcuts
1 Calibration
2 SPM Status
3 All Variables
4 View Logs
5 Device Information
Pressure
1 Sensor Calibration
2 Range Values
3 Current Measurement
4 Last Calibration Points
5 Sensor Limits
Calibration
1 Pressure
Analog Output
2 Analog Output
1 Analog Output
3 Restore Factory Calibration
2 Percent of Range
3 Analog Calibration
SPM Status
1 Detection Status
Detection Status
2 Statistical Values
1 SPM Status
3 Time Stamp
2 SPM Status (cont.)
4 Trends
3 Standard Deviation Sensitivity*
4 Mean Sensitivity**
*If CV is selected, "Coefficient of Variation Sensitivity"
**If CV is selected, this is not shown
Statistical Values
1 Standard Deviation*
2 Mean
*Or Coefficient of Variation
Time Stamp
1 Time Since Detection
2 Total Operating Time
Trends
1 Standard Deviation*
2 Mean
*If CV is selected, "Coefficient of Variation"
All Variables
Primary Variable
1 Primary Variable
1 <Mapped variable>
2 2nd Variable
3 3rd Variable
4 4th Variable
5 Other Variables
2nd Variable
1 <Mapped variable>
3rd Variable
1 <Mapped variable>
4th Variable
1 <Mapped variable>
Other Variables
1 <Unmapped variable>
2 <Unmapped variable>
View Logs
1 Diagnostic Log
Diagnostic Log
2 Pressure Variable Logging
1 Most Recent Status Event
3 Temperature Variable Logging
2 View Other Status Events
3 Total Operating Time
4 Clear Log
Pressure Variable Logging
1 Pressure Variable Log
2 Time Outside Sensor Limits
3 Pressure
4 Total Operating Time
5 Reset All Pressure Events
Temperature Variable Logging
1 Temperature Variable Log
2 Time Outside Sensor Limits
3 Module Temperature
4 Total Operating Time
5 Reset All Temperature Events
Device Information
General
1 General
1 Tag
2 Model Numbers
2 Model
3 Revision Numbers
3 Date
4 Materials of Construction
4 Descriptor
5 Alarm and Security
5 Message
6 Serial Number
Model Numbers
1 Model Number 1
2 Model Number 2
3 Model Number 3
Revision Numbers
1 HART Universal
2 Field Device
3 Electronics SW
4 Electronics HW
5 Sensor SW
6 Sensor HW
Materials of Construction
1 Sensor Module Information
2 Flange Information
3 Remote Seal Information
Alarm and Security
1 Alarm Direction
2 High Alarm
3 High Saturation
4 Low Saturation
5 Low Alarm
6 Write Protect Status
7 Local ZERO/SPAN Buttons
Configuration
Mars 2024
Sensor Calibration
1 Upper Sensor Trim
2 Lower Sensor Trim
3 Zero
Range Values
1 Upper Range value (20 mA)
2 Lower Range Value (4 mA)
Current Measurement
1 Pressure
2 Damping
3 Transfer Function
Last Calibration Points
1 Upper
2 Lower
Sensor Limits
1 Upper
2 Lower
3 Minimum Span
SPM Status (cont.)
1 SPM Insufficient Variability
2 SPM Low Pressure Status
Most Recent Status Event
1 Event 1 - Time since
View Other Status Events
1 Event 2 - Time since
2 Event 3 - Time since
3 Event 4 - Time since
4 Event 5 - Time since
5 Event 6 - Time since
6 Event 7 - Time since
7 Event 8 - Time since
8 Event 9 - Time since
9 Event 10 - Time since
Pressure Variable Log
1 Minimum Pressure
2 Time Since Minimum Event
3 Reset Minimum
4 Maximum Pressure
5 Time Since Maximum Event
6 Reset Maximum
Time Outside Sensor Limits
1 Above Upper Sensor Limit
2 Below Lower Sensor Limit
3 Reset Time Since 1st Events
Temperature Variable Log
1 Minimum Temperature
2 Time Since Minimum Event
3 Reset Minimum
4 Maximum Temperature
5 Time Since Maximum Event
6 Reset Maximum
Time Outside Sensor Limits
1 Above Upper Sensor Limit
2 Below Lower Sensor Limit
3 Reset Time Since 1st Events
Serial Number
1 Transmitter
2 Electronics
Sensor Module Information
1 Serial Number
2 Type
3 Configuration
4 Sensor Range
5 Sensor Limits
6 Isolator Material
7 Fill Fluid
Flange Information
1 Process Connection
2 Process Connection Material
3 O-ring Material
4 Drain Vent Material
Remote Seal Information
1 Number
2 Type
3 Diaphragm Material
4 Fill Fluid
15