2 INTRODUCTION
2.4
START UP
The remote control and the main unit are linked at the Factory. To start up the product follow the
steps described below:
1. Place the batteries inside both remote controls.
2. Open water supply valve
3. Activate the power to supply the CLEANET ALVIA.
EN
If the remote controls need to be linked again, follow the steps of linking process of the remote
controls (see section 2.6).
1
2.5
USE OF THE PRODUCT
When the product is first connected to the mains, it is necessary to wait at least 4 minutes to be able
to perform the first discharge of the toilet.
The CLEANET ALVIA has a small internal water tank that is cold in stand-by conditions.
When the user detector detects a seated user, the preheating process is activated.
The preheating takes place at 36ºC. The functions may be activated at any time, but if they are
activated too soon, the water will not have time to reach the established temperature; therefore it is
recommended a minimum preheating period of 30 seconds from the moment the CLEANET ALVIA
detects the user until any water function is activated.
When a function is activated, the CLEANET ALVIA carries out a cleaning of the nozzle before its use.
When the function is finished and the user leave the toilet, a subsequent cleaning process of the
nozzle takes place for 10 seconds.
After the cleaning process with water, the CLEANT ALVIA will make an hygenization process by
means of an UVC light. The UVC process is always done with the lid closed to protect the user.
The functions may only be activated when the cover is open and the device detects a user.
It is possible to modify the pre-set standard values, customising them to suit the customer´s needs
using the APP.
When pressing any button of the remote control, the leds are activated, informing us of the active
function and the settings that have been selected.
The leds switch off 5 seconds after showing that information.
2
3
ON
6