INDEX
Warning: during downstroke in manual mode the carriage synchronisation system is not active. Manoeuvres to
be carried out correctly and with the utmost care to avoid a dangerous misalignment of the vehicle.
- Lower both carriages, the last reaching the down stop limit resets the block status (acoustic warning off with downstroke
control activated).
- Turn to model
- On the board, set lever (3) to (B) (in automatic).
- Fit the cover of the electric box.
NOTE: manual mode allows only the down movement.
If the manoeuvre cannot be performed, it means that the board is in safety lock because it has detected a dangerous situation.
To reset nut wear stop and the safety lock, proceed as follows:
model
- Turn to
- on the board, set the lever (3) to (A) (in manual);
- simultaneously press the push-buttons P1 and P2 and turn
- press and hold the push-buttons P1 and P2 for 5 seconds;
- the LED (1), already lit, will flash once.
- set the lever (3) to (B) (in automatic).
Caution:
- if the lock status was generated by a faulty hardware (board or electrical system), the lock will occur immediately again;
- if the fault is in the board, replace it;
- if the fault is in the system, remove it.
1
EN_24
0474-M002-0
model
;
P2
P1
B
3
A
2
KPE32 - KPC32