Télécharger Imprimer la page

Ravaglioli KPE32 Traduction Des Instructions Originales page 63

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INDEX
EMERGENCY PROCEDURE: EMERGENCY DROP WITH POWER OFF
Turn the switch to the 0 position (remove the possibility of power supply return).
- EMERGENCY LOWERING: In the event of a power failure, it is possible to bring the load back to the ground by removing the covers
at the top of the columns and turning the actuator screws with a mm17 spanner, alternately the control column and the opposite
column so as not to exceed 50 mm difference between the carriage heights.
Once the electric circuit has been restored, the contactors must be reset by making the lift move up 5 cm and then down.
WARNING! Have this operation carried out by qualified personnel, taking special care to the load position so as to avoid
any unbalance between the two platforms that could affect load stability.
8.4 IMPROPER USE OF THE LIFT
The lift is intended for lifting vehicles with the characteristics specified in ch. 2. and ch. 3.
Any other use is to be considered unsuitable and unreasonable. In particular, the following situations are absolutely prohibited:
1) lifting people or animals
2) lifting vehicles with people inside
3) lifting vehicles containing potentially dangerous materials, (explosives, corrosives, inflammable substances, etc..)
4) lifting vehicles NOT positioned on the pickup points
5) lifting vehicles with accessories not envisaged by RAVAGLIOLI
6) use of the lift by staff who are not adequately trained and authorised.
7) Use it as a jack.
8) Use a single pair of arms longitudinally or transversely.
9) Use a single arm.
10) Use the arms for compressing and crushing.
EN_22
0474-M002-0
KPE32 - KPC32

Publicité

loading

Ce manuel est également adapté pour:

Kpc32Rav.kpe32.198662Rav.kpc32.198709