8.5 SYNCHRONISATION CONTROL DEVICE OPERATION.
Warning!
Checks and emergency procedures must be carried out by a specialised technician due to the presence of
electrical voltage.
The panel contains an electronic board (1) equipped with a LED (2) that stays lit when the switch is in the conditions described below:
Control box reversing device part no. 047303011 - 047303220
Circuit activated for upward movement
Circuit activated for downward movement
Upward movement
Downward movement
Problem: lift blocked (acoustic warning).
Solution: emergency down stroke possible (single down movement).
- If the lift is blocked, it is possible to lower the carriages.
model
- Turn to
- Remove the cover of the electric box.
- Move lever (3) downwards in manual mode (A).
model
- Turn to
Single down movement of carriages. Activate the down stroke control
- push-button P1 to move the carriage of the control column; push-button P2 to move the carriage of the opposite column.
1
P2
P1
B
3
A
model
and simultaneously press:
2
KPE32 - KPC32
0474-M002-0
EN_23