Télécharger Imprimer la page

Ravaglioli KPE32 Traduction Des Instructions Originales page 55

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INDEX
CH. 7
INSTALLATION
7.1 BLOCKS
The lift must be secured to the floor by means of mechanical expansion blocks (HILTI HSL-3 M12 or similar) or by means of chemical
anchors in vials (HILTI HVU-M12 or similar) (with M12 threaded bar made of steel class 5.8 or higher).
As regards the depth of the concrete in relation to the floor level, THE BLOCKS MUST BE LONG ENOUGH TO GET TO THE BEARING
FLOOR. (see fig. A-B).
7.2 CONCRETE
For lower class concrete we recommend the use of suitable chemical anchors.
NOTE It is recommended that the base of the columns be placed directly on the concrete, even if there is a raised floor. However, if
this is of good quality it is possible to secure the columns directly on the floor by using anchors long enough.
EN_14
0474-M002-0
KPE32 - KPC32
EXPANSION BLOCK
LEAN CONCRETE
REINFORCED CONCRETE
CHEMICAL ANCHOR
LEAN CONCRETE
REINFORCED CONCRETE
Fig. A