7. The operator should not be distracted for any reason
during work. Workers needing to access the operating area
must wait for the Operator to stop work on his/her own
initiative, after which they should immediately make their
presence known.
8. It is important for safety that all team members are always
fully aware of each other's intentions in order to avoid
dangerous misunderstandings.
9. The high pressure system must not be started up and run
under pressure without all team members in position and
without the Operator having already directed his/her lance
toward the work area.
3.5
Safety during system maintenance
1. High pressure system maintenance must be carried out
in the time intervals set by the manufacturer who is
responsible for the whole group according to law.
2. Maintenance should always be performed by trained and
authorized personnel.
3. Assembly and disassembly of the pump and the various
components must only be carried out by authorized
personnel, using appropriate equipment in order
to prevent damage to components, in particular to
connections.
4. Always only use original spare parts to ensure total
reliability and safety.
5
TECHNICAL CHARACTERISTICS
Model
Rpm
SS6418
1450
SS6420
1450
SS6422
1450
SS6425
1450
SS6428
1400
Model
Rpm
1450
SN6416
1750
1450
SN6418
1750
Model
Rpm
1450
SN6420
1750
1450
SN6422
1750
1450
SN6425
1750
1450
SN6426
1750
SN6428
1450
Model
Rpm
SW6494
1450
4
Each pump has its own Serial No. XX.XXX.XXX see pos. and
an identification plate see pos. in Fig. 1 which shows:
-
Pump model and version
-
Max revs
-
Absorbed power HP - kW
-
Flow rate l/min - Gpm
-
Pressure bar- PSI
Flow rate
l/min
Gpm
39
10.30
48
12.68
58
15.32
75
19.82
94
24.83
Flow rate
l/min
Gpm
31
8.19
37
9.78
39
10.30
47
12.42
Flow rate
l/min
Gpm
48
12.68
58
15.32
58
15.32
70
18.49
75
19.82
90
23.78
81
21.40
98
25.89
94
24.83
Flow rate
l/min
Gpm
94
24.83
27
PUMP IDENTIFICATION
2
XX.XXX.XXX
2
Mod.
Mat.
Modello
R.P.M.
kW/Cv
Matricola
l.min/GPM
bar/PSI
a brand of
INTERPUMP GROUP S.P.A.
MADE IN ITALY
Mod.
Mat.
Modello
R.P.M.
kW/Cv
Matricola
l.min/GPM
bar/PSI
INTERPUMP
INTERPUMP
GROUP
GROUP
MADE IN ITALY
Model, version and serial number must always be
indicated when ordering spare parts
Pressure
bar
psi
250
3625
210
3045
150
2175
130
1885
100
1450
Pressure
bar
psi
400
5800
400
5800
320
4640
320
4640
Pressure
bar
psi
250
3625
250
3625
180
2610
180
2610
150
2175
150
2175
130
1885
130
1885
120
1740
Pressure
bar
psi
100
1450
1
R.P.M.
kW/Cv
l.min/GPM
bar/PSI
a brand of
INTERPUMP GROUP S.P.A.
MADE IN ITALY
R.P.M.
kW/Cv
l.min/GPM
bar/PSI
MADE IN ITALY
Fig. 1
Power
kW
HP
18.62
25.3
19.25
26.2
16.62
22.6
18.62
25.3
17.95
24.4
Power
kW
HP
23.68
32.2
28.27
38.4
23.83
32.4
28.72
39.1
Power
kW
HP
22.92
31.2
27.69
37.7
19.94
27.1
24.06
32.7
21.49
29.2
25.78
35.1
20.11
27.4
24.33
33.1
21.54
29.3
Power
kW
HP
17.95