Splitwood Log Set SLKRS36
10.3
check pressure readings
Adjust the pilot screw to provide properly sized flame. Turn in a
clockwise direction to reduce the gas flow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read as described on the chart
below. Check pressure with main burner operating on "HI".
Outlet pressure can be checked the same as above using
screw (B). Gauge should read as described on the chart below.
Check pressure with main burner operating on "HI".
After taking pressure readings, be sure to turn screws
clockwise firmly to reseal. Do not over torque.
Leak test with a soap and water solution.
note:
When checking pressures be sure to shield
the valve and wires if wind is present.
Run your pressure hose through one of the
square openings on either side.
Pressure
Natural gas
Inlet
(Minimum 4.5")
Outlet
Natural gas
(Inches)
(Millibars)
*7"
17.4mb
(Minimum 11.2mb)
3.5"
8.7mb
Splitwood Log Set SLKRS42
B
PILOT OUTLET
Propane
(Inches)
11"
B
(Minimum 11")
10"
*Maximum inlet pressure not to exceed 13"
SORTIE DE PILOTE
W415-10001315 / D-0 / 07.10.24
adjustments
TOP VIEW
A
SIDE VIEW
Propane
(Millibars)
VUE DE
32.4mb
A
DESSUS
(Minimum 27.4mb)
24.9mb
VUE DE
CÔTÉ
33
EN