Télécharger Imprimer la page

Napoleon Riverside Serie Manuel D'installation Et D'utilisation page 41

Masquer les pouces Voir aussi pour Riverside Serie:

Publicité

Les langues disponibles

Les langues disponibles

symptom
Pilot sparks but will
Gas supply.
not light.
Out of propane gas.
Pilot supply line may contain
air.
Incorrect wiring / grounding.
Receiver (if equipped).
Valve.
High limit switch tripped.
Burner continues to
Short or loose connection in
spark and pilot lights
sensor rod.
but main burner
does not light.
Dirty, painted, or damaged
pilot assembly components.
Appliance won't
No power to the system.
perform any
functions.
On/off switch in wrong
position.
problem
-
Verify that the incoming gas line ball valve is "open".
-
Verify that the inlet pressure reading is within acceptable
limits, inlet pressures must not exceed 13" W.C.
-
Fill the tank.
-
Repeat ignition process several times or purge the pilot
supply line.
-
Ensure correct polarity of wiring of thermocouple (if
equipped).
-
Verify pilot assembly/valve are properly grounded.
-
Reset program: hold reset button on receiver and wait for 2
beeps. Release after second beep. Press small flame button
on remote within 20 seconds, you will hear an additional
beep (this signals a successful reset).
-
Replace receiver.
-
Check valve and replace if necessary (Do not to overtighten
thermocouple).
-
High limit switch will need to be reset.
-
Button on the back of the switch needs to be pushed, see
"high limit switch location/reset."
-
Verify all connections. Verify the connections from the pilot
assembly are tight. Also, verify these connections are not
grounding out to any metal.
-
Clean using a green Scotch-Brite™ pad to remove any
contamination that may have accumulated on the sensor
rod, pilot hood, ignitor, or flame sensor. Verify continuity with
multimeter with ohms set at the lowest range.
-
Check breaker to verify it is in the "on" position.
-
Ensure module is wired to power correctly.
-
Verify that the switch is in the "on" position.
troubleshooting
test solution
W415-10001315 / D-0 / 07.10.24
EN
41

Publicité

loading

Ce manuel est également adapté pour:

Rss36neRss42neRss36peRss42pe