The appliance includes a finishing flange on the face. Use this as a finish guide for your non-combustible finishing
materials. Facing and/or finishing materials must not interfere with airflow through the front of the appliance and
must never overhang into the appliance opening.
RSS36
A
19 9/16" (497mm)
43" (1092mm)
B
C
38 1/4" (978mm)
D
72" (1829mm)
note:
This appliance has been designed with drainage holes across the front to remove the moisture from the firebox.
Excessive water flow or standing water must be considered when determining a location for your appliance.
It's recommend to provide a slope towards to the front drain ports of the appliance and that the appliance
enclosure allows for the water to drain out.
important:
This outdoor appliance will deflect some water but is not waterproof. The appliance must be enclosed or
covered with materials according to the framing and finishing information in this manual. All joints must be
sealed to prevent water seepage. This appliance will not function as an exterior wall - moisture seepage must be
considered prior to installing on an exterior wall.