Télécharger Imprimer la page

Napoleon Riverside Serie Manuel D'installation Et D'utilisation page 12

Masquer les pouces Voir aussi pour Riverside Serie:

Publicité

Les langues disponibles

Les langues disponibles

3.0 location
EN
It is important when selecting a location for your appliance to ensure clearances to adjacent combustibles are met. This
appliance is intended for installation on an outdoor patio or in your yard. It is highly recommended that this appliance be
installed in a sheltered area (following the guidelines outlined below). Direct wind will cause an erratic flame and possible
pilot or main burner outage. An erratic flame could also lead to excessive carboning (black soot), which is not a safety
issue but is visually undesirable.
note:
When choosing a location for your appliance, care must be taken to avoid areas where excessive moisture or
running water may be a problem.
Ensure at least 30% of the outdoor living space periphery is open and unobstructed.
Any enclosure (shelter) in which the appliance is
used must comply with one of the following:
With walls on all sides, but at least one permanent
opening at ground level and no overhead cover.
Within a partial enclosure which includes an overhead
cover and no more than two sidewalls. These sidewalls
may be parallel, as in a breezeway, or at right angles to
each other.
Within a partial enclosure which includes an overhead
cover and three wide walls, as long as 30 percent or
more of the horizontal periphery of the enclosure is
permanently open.
12
W415-10001315 / D-0 / 07.10.24
Calculate the minimum opening required for an
outdoor living space:
D
D
+
W
+
D
15'
+
18'
+
15'
(4.6m)
(5.5m)
(4.6m)
Divide the width of the open area (W) by the total outdoor
living space:
18'
/
(5.5m)
NOT APPROVED - 0.27 is less than the required 0.30 for
safe installation.
D
+
W
+
D
15'
+
25'
+
15'
(4.6m)
(7.6m)
(4.6m)
Divide the width of the open area (W) by the total outdoor
living space:
25'
/
(7.6m)
APPROVED - 0.31 is more than the required 0.30 for
safe installation.
W
+
W
=
Total
+
18'
=
66'
(5.5m)
(20.2m)
66'
=
0.27
(20.2m)
+
W
=
Total
+
25'
=
80'
(7.6m)
(24.4m)
80'
=
0.31
(24.4m)

Publicité

loading

Ce manuel est également adapté pour:

Rss36neRss42neRss36peRss42pe