B. Insert the center (white/neutral) wire tip through the bottom center terminal
block opening. On certain models, the wire will need to be inserted through
the ground strap opening and then into the bottom center block opening.
Insert the two side bare wire tips into the low er left and the lower right
terminal block openings.
C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do
not overtighten the screws.
After: Conduit
Ground Screw
CAUTION
ALUMINUM WIRING: Aluminum building wire may be used but it must be rated
for the correct amperage and voltage.
3-PRONG POWER CORD DIRECTIONS
IMPORTANT: The neutral or ground wire of the power cord must be connected
to the neutral terminal located in the lower center of the terminal block and the
ground strap must connect the neutral terminal to the ground plate. The power
leads must be connected to the lower left and the lower right terminals of the
terminal block.
DO NOT remove the ground strap con nection.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws from the terminal block.
B. Insert the 3 terminal screws through each power cord terminal ring and into
the lower terminals of the terminal block. Be certain that the center wire
(white/neutral) is connected to the cen ter lower position of the terminal
block.
C. Tighten screws securely into the terminal block. DO not overtighten the
screws.
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower terminal screws on the terminal block. Strip wire to
expose tip about 5/8" long.
EN-23