Before starting the installation process, confirm the installation space meets
the following dimensions and clearances. Do not locate the range where it may
be subject to strong drafts - seal any openings in the wall, floor, or cabinets
in the installation space. Provide adequate clearances between the range and
adjacent combustible surfaces. These dimensions must be met for safe use of
the range. The given dimensions provide minimum clearance. Contact surface
must be solid and level.
The minimum clearance is 0" for the rear of the range. Follow all dimension
requirements to prevent property damage, potential fire hazard, and incorrect
countertop and cabinet cuts.
Countertop surfaces immediately around installation space must be flat and
level for proper installation.
This appliance must not be installed with a ventilation system that
blows air downward toward the range. This type of ventilation system may
cause ignition and combustion problems with the gas cooking appliance
resulting in personal injury or unintended operation.
When the floor covering (hardwood flooring, tile, carpet, etc.) ends at the front
of the range, the area that the range will be installed on must be built up with
plywood to the same level or higher than the floor covering. This will allow the
range to be moved for cleaning and servicing, as well as provide proper air flow
to the range.
Ensure floor covering material can resist temperatures of at least 167 °F (75
°C). Ensure the wall coverings, countertops, cabinets, and any other materials
in contact with the range can resist the heat generated up to 194 °F (90 °C) by
the range.
CABINET DIMENSIONS
Cabinet opening dimensions shown are for 26" (66.0 cm) countertop depth,
24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) maximum upper cabinet depth
C. 30-1/8"(76.5 cm) minimum opening width
D. For minimum clearance to top of cook top, see "*WARNING" below.
E. 30-1/8"(76.5 cm) minimum opening width
F. 3" (7.6 cm) minimum clearance from both sides of range to side wall or
other combustible material.
27 (68.7 cm)
7-4/5 (19.8 cm)
3-1/5 (8 cm)
Cabinet door or hinges should not extend into the cutout.
24 (61.0 cm) base cabinet depth
26 (66.0 cm) tabletop width of base cabinet
EN-17