WARNING
Allow 30" minimum clearance between surface units and bottom of un-
protected wood or metal cabinet, or allow a 24" (61.0 cm) minimum when
bottom of wood or metal cabinet is protected by no less than 1/4" (0.64 cm)
thick flame retardant millboard covered with not less than No 28 MSG sheet
metal [0.015" (0.4mm)], 0.015" (0.4 mm) thick stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
Packaging Removal:
IMPORTANT
TO PREVENT DAMAGE TO APPLIANCE
• Failure to remove packaging materials could result in damage to the
appliance.
Remove all tape and packaging materials. Check for film on stainless steel parts,
padding/spacers on and around door and face of oven, cardboard and plastic on
and around racks, inside storage drawer, etc. Do not use sharp instruments,
rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue.
These products can damage the surface of your range.
Inventory all loose parts against the "Parts Supplied" list.
Check for shipping damage and/or missing parts. Any damage and/or missing
parts should be reported to your local retailer.
To reduce the weight of the range while being moved, adjusted, and installed,
leave the oven racks, and any other accessories to the side until they are ready to
be installed later in these instructions.
Electrical Connection
For power requirements, refer to the following table.
VOLTAGE
120/208VAC
120/208VAC
120/240VAC
120/240VAC
SINGLE TERMINAL
7238W
34.8A/39A
9650W
40.21A/ 50A
EN-18