4-Prong Power Cord Directions
IMPORTANT: The neutral wire of the supply circuit must be connected to the
neutral terminal located in the lower center of the terminal block. The power
leads must be connected to the lower left and the lower right terminals of
the terminal block. The grounding lead must be connected to the frame of
the range with the ground plate and the green ground screw.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws from the terminal block. Remove
the ground screw and ground strap and retain them. Discard the ground
strap. DO NOT DISCARD ANY SCREWS.
B. Insert the one ground screw into the power cord ground wire terminal ring,
through the ground plate and into the frame of the range.
C. Insert the 3 terminal screws (removed earlier) through each power cord
terminal ring and into the lower tenninals of the terminal block. Be certain
that the cen ter wire (white/neutral) is connected to the center lower
position of the terminal block. Tighten screws securely into the terminal
block. Do not overtighten the screws.
After: Power Cord
Terminal
Block
Ground
Screw
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower terminal screws
on the terminal block. Strip wire to exposed tip about 5/8" long.
Neutral
Terminal
Ground Plate
(grounding to
range)
EN-22