Reposition and fix correctly the guards (casings) that may have been removed during maintenance. It is
ATTENTION!
forbidden to start the pump without these guards.
8 – NOISE LEVELS In normal working conditions (without cavitation)
Motor power
9 – STORAGE
General notes
Store the product away from atmospheric agents, in a dry, dust-free place and possibly in its original
packaging.
• Storage temperature: min 0 ° C - max 50 ° C
• Protect the exposed metal surfaces (example flanges) with suitable means to prevent corrosion.
• If you plan to store the pump / group for a long period of time (more than a month) carry out the
following operations on a monthly basis:
ATTENTION!
• In case of problems, replace or restore the damaged parts before starting up. If the pump is stored
after use, make sure to empty the pump using the appropriate drain plug located in the lower part of
the body (See Fig. 5 - Part. 2). If the liquid treated by the pump is harmful to health, it is essential to
observe the following warnings:
• Wear the protective devices and follow the instructions provided in the product technical sheet;
• The liquid must be collected with care and disposed of in compliance with the regulations in force.
• The pump must be washed internally and externally disposing of any residues as mentioned above.
10 – DISPOSAL
INFORMATION TO USERS
pursuant to Legislative Decree No. 49 of March 14, 2014
"Implementation of Directive 2012/19 / EU on Waste Electrical and Electronic Equipment (WEEE)"
This wheeled bin symbol on the product indicates that at the end of its life must be collected separately
from other waste. The user must, therefore, take the remote control integrates the essential
components that got to its life to the appropriate differentiated collection centers for electronic and
electro-technical waste, or return it to the dealer when purchasing a new appliance of equivalent type,
in terms of one to one, or one to zero for equipment having longer side of less than 25 cm. Appropriate
separate collection for the decommissioned equipment for recycling, processing and environmentally
compatible disposal helps prevent negative impact on the environment and human health and
promotes recycling of the materials making up the product. Illegal dumping of the product by the user
entails the application of administrative sanctions stated in Legislative Decree n. Legislative Decree No.
49 of March 14, 2014.
Pag 30 / 48
G.M.P. S.p.A. Via Sale 119/121 – 25064 Gussago (BS) Italy
kW
1450 1/min
≤ 2,2
3 ÷ 7,5
9,2 ÷ 18,5
22 ÷ 30
* APPROXIMATE VALUES and subject to tolerance and coupled motor
• check the correct state of conservation of the whole pump / unit and in particular of the
unpainted surfaces;
• check, with suitable tools, the free rotation of the shaft;
• rotate the shaft manually, in order to keep the bearings protected from the lubricant.
Sound pressure level / * dBA (L
/
/
≤ 75
≤ 85
) – 1m
pA
2900 1/min
≤ 70
≤ 80
≤ 80
≤ 85