EN
5.7
The plunger does not return, or returns more slowly than
usual
/i
Possible cause
The pressure relief valve on the pump is closed.
The couplers are not connected correctly.
The oil reservoir is full.
An undersize hose restricts the oil flow.
The return spring is weak or broken.
The cylinder is damaged internally.
The air pressure return system does not contain
enough air.
5.8
Oil leaks from the external pressure relief valve
(only for hydraulic return cylinders)
/i
Possible cause
The couplers are not connected correctly.
There is a flow resistance in the return line.
6
Maintenance
6.1
General
For standard installation instructions, refer to the Service & Support section of the Holmatro website.
Meticulous maintenance of the equipment preserves the operational safety and extends the life of the
equipment.
WARNING
When performing maintenance activities, always comply with the relevant safety
regulations. Wear the prescribed personal protection equipment.
50
Solution
Open the pressure relief valve on the pump.
Correctly connect the couplers.
Use a pump with a larger oil reservoir.
Use a hose of the correct size.
Have the cylinder repaired by a Holmatro
Certified Technician.
Have the cylinder repaired by a Holmatro
Certified Technician.
Refill the air pressure return system.
Refer to section 6.5.7.
Solution
Correctly connect the couplers.
Install a return line without resistance.
916.000.851_009