5.3
The plunger extends with jerks
/i
Possible cause
There is air in the system.
The plunger is jammed inside the cylinder.
5.4
The plunger extends more slowly than usual
/i
Possible cause
One of the joints leaks.
The couplers are not connected correctly.
The connected pump does not work.
5.5
The plunger extends, but does not retain pressure
/i
Possible cause
One or more of the seals inside the cylinder
leaks.
The connected pump does not work.
One of the joints leaks.
The system is not arranged correctly.
5.6
Oil leaks from the plunger
/i
Possible cause
One or more of the seals inside the cylinder is
worn or damaged.
The cylinder is damaged internally.
The couplers are not connected correctly.
HYDRAULIC CYLINDERS
Solution
Vent the cylinder. Refer to section 6.5.6.
Have the cylinder repaired by a Holmatro
Certified Technician.
Solution
Have the cylinder repaired by a Holmatro
Certified Technician.
Correctly connect the couplers.
Inspect the pump.
Solution
Have the cylinder repaired by a Holmatro
Certified Technician.
Inspect the pump.
Have the cylinder repaired by a Holmatro
Certified Technician.
Re-arrange the system. Make sure that all
components are specified for the load.
Solution
Have the cylinder repaired by a Holmatro
Certified Technician.
Have the cylinder repaired by a Holmatro
Certified Technician.
Correctly connect the couplers.
916.000.851_009
EN
49