8.1 Selecting the File Format
Connecting the storage media causes the the screen to
appear in which the format of the output file with the
welding reports can be selected: a PDF file with an ab-
stracted or extended version of the report or the format
of the welding data management application DataWork.
Using the ñ and ò arrow keys, select the file type you need
and confirm your selection by pressing the START/SET key.
The Service Report option is not important for normal
operation. In the scope of computer-assisted unit service,
this report lists the events related to the maintenance of
the welding unit.
8.2 Downloading All Reports
After the file type was selected, the next screen offers a
"Print All Reports" option. Selecting it will download all
welding reports currently in system memory in the previ-
ously selected file format.
8.3 Downloading by Commission Number, Date or
Report Range
After the file type was selected, the next screen offers a
"By Commission Number," a "By Date Range," and a "By
Report Range" options. Depending on the selection, the ñ
and ò arrow keys can be used to select from the commis-
sions currently in system memory the desired one, of which
the reports should be downloaded, or the alphanumeric
keypad can be used (see Info in Sect. 5.2) to enter a start
date and an end date, or the first and the last report, that
define a range of dates or a range of reports of which the
reports should be downloaded. When you press the START/
SET key, you cause the selected reports to be transferred
to the storage media.
8.4 Understanding the Report Download Process
The download starts automatically after a selection was
made among the options. Wait for all the selected reports
to transfer and the "Download completed" message to
appear on the screen.
If a problem occurs while the download is in progress, a
"Not ready" message shows. After the problem condition
is cleared, the download resumes automatically.