This input is entered either from a bar code using the scan-
ner or manually using the alphanumeric keypad (see Info
in Sect. 5.2). Press the START/SET key to confirm your input.
If the code entered is not correct, a "Code Error" message
appears; check the string of numbers and correct as needed.
If the code entered is correct, it is saved to system memory
and inserted into the welding reports to be printed. By
pressing the STOP/RESET key, you skip this input.
6.5 Entering Weather Conditions
If the weather conditions feature is enabled in the system
set-up, this input is required before the fitting code can
be entered.
Use the arrow keys ñ, ò to select from "sunny," "dry,"
"rain," "wind," "tent," and "heating." Press the START/
SET key to confirm your selection. The selection is saved
to memory and will appear in the printed welding report.
6.6 Entering Data on the Jointed Components
According to the same procedure as used for entering
the fitting traceability code (see Sect. 6.4), prior to the
welding proper the ISO-compliant codes of the pipes to
be welded, their length as well as the installing company
can be entered for inclusion in the welding reports. For
this to be possible, they have to have been enabled in the
configuration menu.
7 Entering Welding Parameters Manually
To be able to enter the welding parameters manually, you
have first to connect the fitting to the welding unit with
the welding cable. The manual input of the parameters can
then be accessed by pressing the ò arrow key. The screen
will show a menu as reproduced in Display 12, provided
manual input is enabled in the configuration menu (see
Sect. 10.1). In other words, the manual parameter input
replaces reading the bar code of the fitting with a scanner.
Using the arrow keys ñ and ò you can select "Enter Volt-
age/Time" or "Enter Fitting Code" (i.e., the numbers that
represents the code of the fitting to be used). Confirm your
selection by pressing the START/SET key.
7.1 Manually Entering Welding Voltage and Time
If this option was chosen in the manual parameter input
menu, a display like the one to the right appears on the
screen. Use the alphanumeric keypad (see Info in Sect. 5.2)
Version April 2016
HÜRNER HST 300 HP 2.0 User's Manual
****
WEATHER
****
>sunny
dry
rain
Display 11
**
MANUAL INPUT
**
>Enter Voltage/Time
Enter Fitting Code
Display 12