DIAGNOSTIC SYSTEM
If abnormal conditions exist in any sensor sig-
nal being sent to the control unit, the self-diag-
nostic system warns of the abnormal condition.
If this system activates, the caution lamp will
flash.
Also incorporated is a fail-safe provision that
allows the operation at a restricted speed even
under such a failure condition.
NOTE:
• Each time the starter system is operated, the
caution lamp will light briefly for the first two
seconds.
• The failed system can be identified by the
mode of the caution lamp flashing.
This diagnostic code is designed to appear
while the engine is running.
NOTICE
If the diagnostic system activates while
you are operating your outboard motor,
there is an abnormal condition in one of
the sensor signals of the control system.
Consult your authorized Suzuki marine
dealer for repair of the control system.
OIL CHANGE REMINDER
SYSTEM
This system informs the operator of the time for
replacing engine oil on the basis of the mainte-
nance schedule.
The system is designed to register the total
operating hours of the outboard motor and
function its operation when the preprogrammed
hours have reached.
(Refer to the INSPECTION AND MAINTE-
NANCE section and the last page.)
SYSTEM ACTIVATION
When the total operating hours have reached
the preprogrammed hours, the caution lamp will
flash while the engine is running. This indication
will repeat until you cancel the system activa-
tion.
CANCELLATION
1. Start the motor.
Make sure that the motor is in "Neutral" and
the throttle grip is fully closed.
NOTE:
The engine stops when the engine stop button
is kept to push more than 0.5 seconds.
2. Push the engine stop button 1 three times
within three seconds so that the engine
should not stall.
The caution lamp is no longer lit when the
reminder cancellation is successful.
3. Stop the engine.
23