Télécharger Imprimer la page

Scotsman HID207 Manuel D'installation Et D'utilisation page 7

Publicité

Les langues disponibles

Les langues disponibles

HID207
User Manual
Placement
The location of the equipment should be selected
with care. Consideration should be given to allow
adequate space on the sides for these air cooled
models to breathe.
Minimum clearances:
• 6 inches or 15 cm at each side
• 2 inches or 5 cm above, 10" or 25 cm more to
allow auger removal when ceiling is fixed.
• 6 inches or 15 cm at the back.
Airflow Direction
Air flows air left to right. More space than the
minimum at the sides will maximize performance.
The power outlet must be located within the length
of the supplied power cord. If placed on a counter,
the counter must be strong enough to support the
weight of the unit. Space above the cabinet should be
allowed for service and maintenance. If legs will be
used, allow space for the total cabinet height.
Placement in a small room will require ventilation to
exhaust the heat they produce. They also produce
some added noise from the fan. Noise sensitive areas
should consider locating the machine where the noise
from ice making is not objectionable.
Nearby infrared emitters or a window that allows
sunlight to shine on a dispensing sensor (only on
model HID207AX) may cause the unit to dispense ice
or water without a container to trigger it.
Model Information
Model
Voltage
volts/Hz/phase
HID207AX-1A
115/60/1
HID207ABX-1A 115/60/1
Cafeteria applications.
Note: Limited application due to small capacity.
The unit can be placed in a cafeteria line for ice and
water. As some users sometimes dispense too much
ice, high volume use may require the drip tray to be
occasionally cleared of ice.
Caution:
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system,
but if released it may be flammable.
Uncrating
The unit is attached to a wooden skid by 3 interior
hex head fasteners. Use a 7/32 inch hex wrench to
unscrew them.
Remove clear protective covers from dispense
sensors.
Dimensions
(w" x d" x h")
16.05 x 17.53 x 23.78 11.8
16.05 x 17.53 x 23.78 11.8
March 2024
Page 5
MCA Condenser
Refrigerant
Type
(R-290)
Forced air
3 Oz
Forced air
3 Oz
Clear
Covers
Dispense
Trigger
Photo Eye
Button

Publicité

loading