SECTION 8 − TROUBLESHOOTING
8-1. Troubleshooting Table
Trouble
Motor/blower will not start or continue
running.
Decreased air flow.
Fume extractor discharges fumes or
particles.
8-2. Error Flash Codes Of Service Indicator Light H1
Error Code
Problem
1X Flashing
Power supply error.
2X Flashing
Motor protection switch
activated.
3X Flashing
Maintenance interval
reached/exceeded.
4X Flashing
Filter Condition.
5X Flashing
Safety shut down
activated.
Check input power connection.
Check fuse F1, and replace if open (see Section 7-3)
Check relay F6, and reset if open (see Section 7-3).
Have Factory Authorized Service Agent check unit.
Reconnect collection hose to connection port.
Inspect collection hose and replace if damaged.
Remove obstruction from inside of collection hose.
Verify air supply is connected for automatic filter cleaning.
Replace filter (see Section 7-2).
Have Factory Authorized Service Agent check unit.
Inspect filter (including gasket) and replace if damaged or dirty. Be sure filter is installed properly.
(See Section 7-2).
Check seal between upper and lower units.
Have Factory Authorized Service Agent check unit.
Possible Cause
−Polarity wrong.
−Phase Failure.
−Undervoltage/overvoltage detected.
Input power too high.
1600 hour maintenance interval
exceeded.
The differential pressure is at least
2500Pa.
The maximum allowed differential pres-
sure has reached 3000 Pa. The unit
has automatically shut down.
Remedy
Remedy
Check input power connection (See Section 5-7).
−Turn off unit.
−Wait for automatic reset of the motor protection switch.
−Restart unit.
−If error persists, contact an Authorized Factory Service
Agent.
Perform scheduled 1600 hour maintenance (see Section
7-2).
Perform scheduled 1600 hour maintenance (see Section
7-2). If required maintenance is not performed, the unit auto-
matically shuts down when a pressure difference of 3000Pa
is detected.
Perform scheduled 1600 hour maintenance (see Section
7-2). If required maintenance is not performed, the unit auto-
matically shuts down when a pressure difference of 3000Pa
is detected.
OM-252565 Page 25