7-2. Scheduled 1600 Hour Maintenance
.
Perform these maintenance procedures when indicated by Service Indicator Light (See Section 7-1 and/or Section 8-2 ), or more often in severe
conditions. If these procedures are not performed, unit may shut down (see Section 8-2).
A. Replacing Particulate Collection Bag And Draining Water From Compressed Air Tank
3
1
2
4
6
5
7
Tools Needed:
!
Turn off unit and disconnect in-
put power connector before re-
placing particulate bag or drain-
ing water from compressed air
tank.
!
Do not operate unit without a
particulate bag in place.
!
Do not breathe the particles col-
lected by the fume extractor.
Wear approved safety equipment
(respirator, gloves, long sleeve
shirt) when servicing filter and
spark guard. Dispose of used
bag and collected particles ac-
cording to local, state, and feder-
al requirements.
!
Read and understand the Materi-
al Safety Data Sheets (MSDSs)
and the manufacturer's instruc-
tions for metals, consumables,
coatings, cleaners, and de-
greasers.
Draining Water From Compressed
Air Tank
1
Input Power Receptacle
2
Compressed Air Supply
Disconnect unit from compressed air
supply.
3
Drain Valve
Turn valve counterclockwise to open
valve.
Close valve when water is finished
draining.
Changing particulate Collection Bag
4
Air Vacuum For Particulate
Collection Canister (Hose)
5
Latches (3)
6
Particulate bin
Disconnect hose.
Open the three latches.
Carefully lower particulate bin and re-
move particulate bag.
Install new particulate bag.
If filter is not being replaced at this time,
reverse order to reinstall particulate bin.
7
1600 Hour Service Timer Reset
Switch
Reset 1600 hour service timer (See
Section 7-2B).
.
If filter is being replaced at this time,
proceed to Section 7-2B.
Ref. 255 618-A / Ref. 255 687-A