5-1. Serial Number And Rating Label Location
The serial number and rating information is located on the back of the unit. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
5-2. Selecting A Location
SECTION 5 − INSTALLATION
1
2
18 in
(460 mm)
!
Only qualified persons should in-
stall, operate, maintain, and repair
this unit.
!
Installation must meet all National,
State, and Local Codes − have only
qualified
persons
installation.
!
Do not move or operate unit where it
could tip.
!
Do not use this equipment to support
personnel, large tools, or other
material.
!
Special installation may be required
where gasoline or volatile liquids are
present − see NEC Article 511 or CEC
Section 20.
Moving The Equipment
1
Lifting Forks
Use lifting forks to move unit.
Extend forks beyond opposite side of small
containers and beyond midpoint of larger/
longer containers.
Compressed Air And Power Supplies
2
Compressed Air Supply
(72− 87 psi/496 − 600 kPa)
(3/8
in. Barbed Fitting On Unit)
Clean, dry, oil-free compressed air is need-
3
ed for the cleaning system to operate
properly.
3
AC Power Supply
A dedicated 460 volt AC individual branch
circuit protected by time delay (type J) fuses
or circuit breaker is required for each unit.
See Section 5-7.
Position unit near the welding operation and
close to compressed air supply and 460 volt
AC power supply. Keep unit way from ob-
structions that may restrict movement of the
fume collector or extraction arm. Be sure
equipment is accessible for maintenance.
Ref. LocFiltair_Mobile2 2016-04 800 402-A / 255 618
make
this
OM-252565 Page 13