5-5. Installing Input Power Plug
1
5-6. Electrical Service Guide
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output of the electrical equipment.
Input Voltage (V)
Rated Maximum Supply Current I
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 2014 National Electrical Code (NEC) (including Article 430)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" . See UL 248.
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amps), and UL class "H" ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.
L3
2
(A)
1max
1
2
Time-Delay Fuses
3
Normal Operating Fuses
4
4
2
L2
L1
GROUND
!
Installation must meet all Na-
tional and Local Codes − have
only qualified persons make
this installation.
1
Input Power Cord
Select cord according to Section 5-6.
2
Input Power Connector
(Supplied)
Strip insulation from end of each wire
in cord and attach wires to connector
as follows:
 Green Or Green/Yellow Wire To
Ground Terminal
 Black Wire To L1 Terminal
 White Wire To L2 Terminal
 Red Wire To L3 Terminal
253775-A
Filtair Elec Serv 2015−07
60 Hz Three-Phase
460
13.5
15
20
14
216 (66)
14
OM-252565 Page 15