Standard models
PRO speed
230 V, 1Ph, 50/60Hz, 16A
CE
UL
240 V, 1Ph, 50/60Hz, 16A
JA
200 V, 1Ph, 50/60Hz, 20A
1
6a
18
2.5
ATTENTION.: Any intervention on the electrical system
and the connection of a plug (when necessary),
must be performed only by a qualified electrician, in
compliance with the applicable standards and national
laws and/or local regulations.
The standard models of the tyre changers have
specific electrical specifications and are supplied
according to the different power supplies that they
will be connected to; See the table aside
The electric motors operate with a voltage tolerance;
equal to more or less 10%.
The power supply cable, which is always provided
with the machine, must be fitted with an adequately
sized type-approved plug, in compliance with the
applicable standards in the destination country.
For the installation technician
The qualified electrician, when fitting a plug, must
refer to the data clearly set out on the plate found on
the machine electrical cable.
PRO speed
The user must ensure that the electrical system
that the machine is connected to is fitted with 10 A
delayed fuses (In case of machine with INVERTER
20 A (25 A for Japan)), or alternatively, an equivalent
automatic magneto-thermic switch.
Check that there is an efficient earthing system.
Once the connection is complete, press the self-
centring rotation pedal downwards (1, Fig. 6a) and
check that it rotates clockwise.
Check that the power supply system is fitted with an
automatic cut off device against overcurrents, with a
differential calibrated to 30 mA.
WARNING: IF INVERTERS ARE PRESENT, ONLY
USE TYPE B RESIDUAL CURRENT OPERATED
CIRCUIT BREAKERS.
2.6
The tyre changer is equipped with a pressure limiting
valve which limits pressure from connected inflating
devices to a maximum of 3.5 bar.
Removing or tampering with this safety valve
(pressure limiter) is a violation of European Safety
Regulations and will relieve the manufacturer from
all liability.The compressed air outlet may only be
used to connect inflating devices. If the machine
is connected to the compressed air network at this
outlet, the compressed air system and safety devices
will be destroyed.
The pressure in the compressed air network must
not exceed 16 bar.
For pneumatic connection of the machine make sure
the jaws remain closed (risk of personal injury) and
proceed as follows:
• Connect the supplied bayonet connector to the
compressed air inlet.
• At this connector, connect the tyre changer to
a compressed air network (operating pressure
8 to 10 bar) using a compressed air hose with
an internal diameter of 8 mm / 5/16".For further
details, consult the pneumatic diagram shown in
the spare parts list.
Electrical connection
Pneumatic connection