2
12
2.
Machine installation and
connection
During installation and connection observe Health
and Safety regulations.
2.1
Installation
The tyre changer can be installed on any reinforced
concrete surface or on any floor with a similarly hard
covering.
When choosing the installation site, consider not
only the type of floor, but also Health and Safety at
Work and accident prevention regulations.
For installation on a higher floor, check the
load-bearing capacity of the floor. We normally
recommend that you consult a construction expert
before installation on a higher floor.
Machine dimensions are given in Fig. 1 and in § 11.
Technical specifications.
2.2
Mechanical reassembly
WARNING: THE WORK DESCRIBED BELOW
MUST BE DONE BY A TECHNICIAN AUTHORISED
BY THE DEALER.
To optimise the packaging or to guarantee greater
safety during transportation, the machine may be
delivered with some parts disassembled.
Upon receiving the machine, some important parts
may need to be reassembled. Although these are
simple operations, we recommend that you follow
the instructions provided below.
Mounting the vertical column (Fig. 2):
A.
Remove the column base guard (1) and the two
lateral holders (if present) from the machine. Cut and
remove the straps holding the shaped washers (2) in
position.
B.
Lift the column (0) with an appropriate lifting tool
(crane, fork lift) and a belt of sufficient capacity (200
kg). A second person is required to help with this
operation. BE CAREFUL NOT TO DAMAGE THE
AIR HOSES (3). Insert the air hose through the hole
"H" in the cabinet.
C.
WARNING: Before inserting the column fixing pin
(4), grease and position the shaped washers (2), as
illustrated. Insert the column in its seat, then fit the
pin (4), the two tapered bushings (5), the washers
(6) and the nuts (7). Tighten the nuts evenly on both
sides and manually finish tightening until the tapered
bushings are locked in the seats.