SEAR STATION
BURNER IGNITION
®
Summary lighting instructions are inside the left-hand cabinet door.
Failure to open the lid while igniting the grill's burners, or not
waiting five minutes to allow the gas to clear if the grill does
not light, may result in an explosive flare-up which can cause
serious bodily injury or death.
The Sear Station
burner has an on or off control setting. To ignite the Sear Station
®
burner, you must first ignite the two adjacent main burners.
Adjacent Main Burner Snap Ignition
Note: Each main burner control knob snap igniter creates a spark from the igniter electrode
to the burner lighting tube. You generate the energy for the spark by pushing in the control
knob and turning it to START/HI. This will ignite each individual burner.
m WARNING: Check hose before each use of grill for nicks,
cracking, abrasions or cuts. If the hose is found to be damaged
in any way, do not use the grill. Replace using only Weber
authorized replacement hose. Contact the Customer Service
Representative in your area using the contact information on
our web site.
Log onto www.weber.com.
A) Open the lid (1).
B) Make sure all burner control knobs are turned off (2). (Push control knob in and
turn it clockwise to ensure that it is in the OFF position.)
m WARNING: The burner control knobs must be in the OFF
position before turning on the liquid propane tank valve. If they
are not in the OFF position, when you turn on the LP tank valve,
the "excess gas flow control" feature will activate, limiting the
flow of gas from the LP tank. If this should occur, turn off the
LP tank valve and burner control knobs. Start over.
When the "excess gas flow control" feature is activated, a small
amount of gas is still flowing to the burners. After turning off
the tank and burner control knobs, wait at least five minutes for
the gas to clear before attempting to light the grill. Failure to do
so may result in an explosive flare-up, which can cause serious
bodily injury or death.
C) Turn the LP tank on by slowly turning the tank valve counterclockwise; wait 60
seconds (3).
m WARNING: Do not lean over the open grill.
D) Ignite each main burner that is adjacent to the Sear Station
knob in and turn it to START/HI until you hear the igniter snap; continue to hold
control knob in for two seconds. This action will spark the igniter, the burner
lighting tube, and then main burner.
E) Check that the burner is lit by looking through the cooking grates (5). You should
see a flame. If burner does not light on first try, push control knob in and turn it to
OFF. Repeat lighting procedure a second time.
Sear Station
Burner Lighting: Ignition by an Adjacent Ignited Main Burner
®
burner control knob to the ON position (6).
F)
Turn Sear Station
®
G) Verify burner ignition by visual inspection of a flame (7).
m WARNING: If ignition does not occur in five seconds, turn
burner control OFF, wait five minutes, and repeat steps F
& G, or see "SEAR STATION
instructions.
m WARNING: If the burner still does not light, turn the burner
control knob to OFF and wait five minutes to let the gas clear
before you try again or try to light with a match.
Note: See "MAINTENANCE" for burner removal and cleaning
procedure.
◆
20
SEAR STATION
m DANGER
m DANGER
(4). Push the control
®
BURNER MANUAL IGNITION"
®
IGNITION & USAGE
®
1
®
2
®
4
The grills illustrated in
this Owner's Guide may
vary slightly from the
model purchased.
TO EXTINGUISH
Push in and turn each burner control knob clockwise to OFF position. Turn gas supply
off at the source.
◆
APAGADO
ARRÊTÉ
OFF
ON
5
7
6
3
2
6