BUILT-IN GAS LINE LOCATIONS
Note: Leave an access in the "island" structure for gas supply and regulator service that is
not inside the grill structure.
Note: Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid
possible damage to gas supply lines. Exercise caution when pulling gas lines through built-in
structure.
General Specifications for Piping
Note: Contact your local municipality for building codes regulating outdoor gas grill
installations. In absence of Local Codes, you must conform to the latest edition of the
National Fuel Gas Code ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation
Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for
Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational
Vehicle Code, as applicable.
• This grill is designed to operate at 11 inches of water column pressure. An LP in-line
regulator may be necessary for this pressure.
m CAUTION: If young children are in the area, a locking valve
should be considered.
• Pipe compound that is resistant to the action of liquid propane gas should be used
when gas connections are made.
• The gas connections must be firmly attached to rigid, permanent construction.
Note: The information provided in this manual is general for typical installations. We cannot
cover all possible installation ideas. We recommend that, prior to installation, you contact
your municipality for local building codes and your local fire department for installation
verification.
If you have any questions, contact Customer Service at 1-800-446-1071.
26
GAS SUPPLY
1
16
2
11
3
2
a
b
c
BUILT-IN GAS LINE LOCATIONS
1
3
2
460
660
" (419.1 mm)
16
" (419.1 mm)
1
1
2
2
" (282.6 mm)
11
" (282.6 mm)
1
1
8
8
" (63.5 mm)
2
" (63.5 mm)
1
1
2
2
Plan view right
Side view
Gas inlet
a
1
2
c
3
b
TOLERANCES
±
" (3.2 mm)
1
8
±
" (3.2 mm)
1
8
±
" (3.2 mm)
1
8