When replacing worn or damaged parts, original
spares must always be used.
Special maintenance operations (non included in
this handbook) require a specialised workshop on
Changing and replacing the drilling cups
The dispenser can have up to six drilling cups fitted on
it.
In the set-up with one or two drilling cups, you will need
to fit the phasing units to ensure dispenser integrity (see
"Drilling cups arrangement" - page 5).
UN41 0098GF
Proceed as outlined below.
1)
Lift the work vehicle off the ground.
2)
Unscrew the screws (A).
3)
Remove the mobile guard (B).
4)
Unscrew the screws (C) on each drilling cup (D) and
remove it.
Set up the drilling cup control disk and any phasing
units required (see "Drilling cups arrangement").
English language
INFORMATION CONCERNING REPLACEMENTS
D
C
C
A
the premises which meets the requirements speci-
fied by the relative laws in force (appropriate equip-
ment suitably trained staff etc.); if you do not have a
compliant workshop, contact an authorised one.
Caution
To prevent damage to the transplant unit transmis-
sion, use the driving wheel to rotate the dispenser.
E
C
5)
Fit the cups in the housings.
6)
Tighten the screws (C) on each drilling cup.
7)
If necessary, fit the phasing unit/s (F).
8)
Tighten the screws (E) on each phasing unit.
9)
Fit the casing (B) and tighten the screws (A).
10) Lower the work vehicle onto the ground.
30
8
F
E
E
A
B
Use and maintenance