9.
insTallaTion
9.1.
safety instructions
Warning!
Danger - improper installation!
Improper installation may result in injuries as well as damage to
the device and the area around it.
•
Fluid and electrical installations may be carried out by author-
ised technicians only and with the appropriate tools!
Danger due to unintentional activation of the equipment!
Unintentional activation of the equipment during installation work
may result in injuries and/or damage.
•
Take appropriate measures to prevent the equipment from being
unintentionally activated.
9.2.
Electrical installation
Danger!
risk of electric shock!
There is a serious risk of injury when reaching into the device.
•
Before starting work, always switch off the power supply and
safeguard to prevent re-activation!
•
Observe applicable accident prevention and safety regulations
for electrical equipment!
•
Attach earthing cable via the earthing screw!
All manuals and user guides at all-guides.com
Type 3005
Installation
Check on the rating plate of the rotary actuator whether
the indicated voltage corresponds with the mains voltage.
Cables with a diameter of 7 to 12 mm are permitted for
the electrical installation. The utilized cables must have an
upper limit temperature of at least 80°C.
preparatory work:
→
Remove stainless steel screws 3 for the hood 2 and carefully
remove the hood (see Fig. 1: to Fig. 3:).
9.2.1.
Earth connection on outside or
inside
The earthing cable for the power supply and control must be attached
with the earthing screw 16 (M5) to the outer housing (see Fig. 1: to
Fig. 3:).
procedure:
→
Loosen earthing screw 16 and attach eyelet of the earthing cable
with the earthing screw (see Fig. 1: to Fig. 3:).
→
Optionally the earthing screw can be connected to Pos. A of the
power supply card.
→
To do this, loosen earthing screw and attach eyelet of the earthing
cable with the earthing screw.
english
23