Les langues disponibles

TechnicalData
7.4.3.
Electrical Data
Connections:
2 cable bushings ISO M20 (device plug EN
175301-803 on request)
Limit switches:
2 adjustable limit switches for the motor
2 potential-free limit switches (for position
feedback)
Output: max.
250V AC / 5A
Electrical data for standard version without analogue signal
and position controller version with 4 ... 20 ma, 0 ... 20 ma or
0 ... 10 V analogue input signal
90° actu-
torque
ating time
[nm]
[s]
25
7
45
15
75
20
100
15
All manuals and user guides at all-guides.com
Type 3005
Voltage /
power
frequency
input
[V / hz]
[W]
45
100-240 / 50/60
24 AC / DC
45
100-240 / 50/60
24 AC / DC
45
100-240 / 50/60
24 AC / DC
45
100-240 / 50/60
24 AC / DC
90° actu-
power
torque
ating time
[nm]
[s]
150
30
300
50
600
38
1 000
38
We recommend an actuator designed with 1.5 times the
maximum torque of the fitting (with 2 times the maximum
torque for variable speed actuators).
english
Voltage /
frequency
input
[V / hz]
[W]
45
100-240 / 50/60
24 AC / DC
85
100-240 / 50/60
24 AC / DC
250
230 V AC
250
230 V AC
19