Télécharger Imprimer la page

Burkert 3005 Démarrage Rapide page 27

Masquer les pouces Voir aussi pour 3005:

Publicité

Les langues disponibles

Les langues disponibles

procedure:
Remove glass hood of the position indicator 1 including the sealing
ring by loosening the four fastening screws and remove the glass
hood (see Fig. 12:Removing hood).
Remove position indicator (see
Remove hood 2 by loosening the four fastening screws 3 (see
14:Removing hood).
adjusting cams for limit switch contacts
Cam
Key
Adjustment travel
Fig. 15:
Adjusting limit switch
clockwise
procedure:
Adjust the two upper cams with a suitable key (see
Fig. 16:).
On completion of the adjustment work, re-attach the hood 3, the
position indicator, the seal and the glass hood 1.
22
All manuals and user guides at all-guides.com
Fig. 13:).
Cam
Key
Adjustment travel
Fig. 16:
Adjusting limit switch
anti- clockwise
Fig. 15: and
english
The rotary actuator is supplied ex works with the following
settings:
The limit switch CLOSED (FCF) is actuated by the cam
(closed position).
The limit switch OPEN (FCO) is preset to a rotation angle
Fig.
of 90°.
Type 3005