Manufacturer
Lubricant
RENOLIN 212
RENOLIN DTA 220
Mobil DTE Oil BB
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Check the oil level and top up if necessary using the oil
dipstick pos. , Fig. 3.
Viscosity / Room Temperature diagram
mm
/s = cSt
2
The used oil must be poured unto a suitable container and consigned to an authorized recycling center.
Do not release used oil into the environment under any circumstances.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing: the
oil dipstick, pos. , and then the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
the table in Fig. 14 chapter 11.
The quantity required is ~ 2 liters.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0 °C - 30 °C,
follow the instructions in the following diagram, considering
that oil must have a minimum viscosity of 180 cSt.
Ambient temp. (°C)
24
Fig. 3