Design Guide - Single Standard Installation
SINGLE STANDARD INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
*83 1/2" min.
*84 1/2" max.
(212.1 – 214.6)
*Trim will overlap
additional 5/8"
Water And Electrical Locations
Electrical and water supply must be located as shown.
For 24" Deep Cutouts
A trim kit (ZKW36V) is required for standard
installations.
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Refer to Dim A on page 6 for clearances needed for
door swing.
31-1000600 Rev. 0
35-1/2" (90.2) or
36" (91.4)
9"
18"
(22.9)
(45.7)
8"
9"
(20.3)
(22.9)
6"
ELECTRIC
WATER
(15.2)
24" (61)
6" (15.2)
24 7/8"
Finished
(63.2)*
Return on both
sides and top
2 1/2" (6.4)
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power supply
is recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as shown.
The water line should be 1/4" O.D. copper tubing or
QuickConnect
kit (WX08X10006) between the cold
™
water line and water connection location, long enough
to extend to the front of the unit (8' [2.4m]). Installation
of an easily accessible shut-off valve in the water line
is required.